The OWZA comes pre-wired with a NEMA L14-30P twist-
lock plug (250 volt, 4-prong). For export models, a NEMA
L6-30 twist-lock plug (250 volt, 3-prong) is used.
Dual Dixell XR03CX digital controllers are provided for
case operation and programming. The controllers are located
inside the electrical junction box and are utilized according to
your temperature preference: low-temperature operation only
uses the left-hand controller while medium-temperature opera-
ELECTRICAL CONNECTIONS
NEMA L6-30 PLUG
(TWIST LOCK)
BREAKER
SWITCH
MODEL
OWZA
tion utilizes on the right-hand controller.
The case is turned ON/OFF via an electric breaker that is
located on the electrical junction box, in the left-hand side of
the case behind the front kick plate.
NOTE: Dixell controller information and user setpoints can
be found in this manual's Appendix section.
DIGITAL
CONTROLLERS
NEMA L14-30P PLUG
(TWIST LOCK)
9